HC2-S3

The HC2-S / HC2-S3 is the most versatile probe from ROTRONIC and forms the basis of the product portfolio. It measures humidity and temperature and calculates the dew/frost point.

Download Datasheet »

Contact me about this product Request Product Demonstration

The HC2-S / HC2-S3 is the most versatile probe from ROTRONIC and forms the basis of the product portfolio. It measures humidity and temperature and calculates the dew/frost point.

Applications
HVAC, food industry, building services equipment, paper, textile and pharmaceutical industries

Features
• Accuracy: ±0.8 %rh, ±0.1 K, at 23 °C ±5 K
• Range of application: -50…100 °C / 0…100 %rh
• Digital interface (UART) and scalable analog outputs, 0…1 V
• Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
• Adjusted at 23 °C and 10, 35, 80 %rh

 

Applications

  • Meteorological

Probe type

Meteorological probe

Dimensions

Ø15 x 83 mm

Weight

10 g

Operating range electronics

-40…100 °C / 0…100 %rh

Accuracy at 23 ±5 °C

±0.8 %rh / ±0.1 K

Accuracy w. adjustment profile "standard"

at 23 °C / 10, 35, 80 %rh ± 0.8 %rh / ± 0.1 K

Power supply / Power consumption

3.2...5 VDC, Calibration @ 3.3 VDC / ~4.5 mA

Long-term stability sensor

<1 %rh / year

Humidity sensor

Hygromer IN-1

Temperature sensor

PT100 1/3 DIN Class B

Probe protection

Polycarbonate plastic cage, white

Filter cartridge

Polyethylene dust filter, white, 40 um

Response time t 63

<15 sec.

Allowed wind speed

20 m/s, with filtre

Psychrometric calculations

Dew or frost point

Reproducibility Airchip

<0.02 %rh / 0.01 K

Exploitation software

ROTRONIC HW4.2

Probe adjustment by software

1 Point & multipoint %rh & °C

Firmware update

With internet and HW4 software

User information

from Software HW4 (devicemanager)

Data processing via HW4

with interface cables

Device Protection by password

Yes

Type of output signals

2 x 0…1 VDC

Analogue outputs scaleable by the user

Yes

Analog output signal (standard)

0…1 V = 0…100 %rh; 0…1 V = -40…60 °C

Digital output signal (standard)

UART

Communication interfaces

UART

Service Interface

UART

Reverse voltage protection

Mechanically in the connector

Max. cable length service cable

5 m

Enclosure material

Polycarbonate

FDA/GAMP compatibility

FDA 21 CFR Part 11 and GAMP compatible